IBEX™ Specifications

Ref Feature Specification
1 Performance Characteristics
1.1 Direction Provides support on both ascent and descent
1.2 Load support capability Level of assist manually set by climber at the ECC from 50 to 125 lbs at 25-lb intervals
1.3 Climb speed Load support provided is constant regardless of speed of climb up to 120 ft/min, up to power limit of motor
2 Motor and Drive
2.1 Motor type 90V PMDC 0.5HP brush motor provides variable speed and torque
2.2 Power supply User supplied at tower: 110 Vac/60 Hz/1 Ø/ 500W or 230 Vac/50 Hz/1 Ø/ 500W
2.3 Mounting Motor and drive unit fixed to rungs at base of ladder. Max width 7.1” (18cm). Adjustable to fit rung spacing from 10-14” (25 to 35.5cm)
3 Belt
3.1 Configuration Continuous loop
3.2 Belt material and diameter 10.5mm round reinforced polymer
3.3 Belt weld and adjustment Tensioning and thermowelding kit required for installation
4 EasyClimb Controller
4.1 Controls Stop button and Up/Down buttons for load support adjustment. LED lights indicate different assist settings.
4.2 Power supply Rechargeable NiMH battery
4.3 Wireless signal Wireless communication complies with US Code of Federal Regulations (CFR), Title 47. Part 15 for US, R&TTE Directive 1999/5/EC for EU..
6 Environmental
6.1 IP Rating IP54
6.2 Corrosion Class 3 corrosion resistance
6.3 Temperature Tolerance -30 F to +105 F (-35C to +40C) Operating -40F to +140F (-40C to +60 C) Storage
6.4 Noise Level <75 dB 5 ft from motor